Copper Conductor Mineral Filler Mi Cable , LSZH Jacket Micc Wire

Ask Latest Price
Video Channel
Brand Name :DONGJIAXIN
Model Number :BBTRZ
Certification :QS
Place of Origin :CHINA
MOQ :Negotiable
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :100KM/Week
Delivery Time :7-15 working days
Packaging Details :Steel wooden drum
Model name :BBTRZ
Type :fireproof cable
Insulation :XLPE+ mineral substance
Nos.of Core :2~5
Conductor Type :stranded annealed copper Class 2
Sheath :PVC
Keywords :fireproof cable,BBTRZ,Mineral fire-Proof cable
Fire performance :IEC 60332-1
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Copper Conductor Mineral Filler and LSZH Jacket MI Cable

BBTRZ Mineral Insulated Fire Resistant Cables, 0.6/1kV, plain annealed strand copper wire, Inorganic

mineral insulated compound (with MICA tape), XLPE isolated layer, mineral fire protection layer, LSZH

compound sheath, meet to BS 6387, IEC 60702, JG/T 313-2014, GB/T 34926-2017.

Application:

Industry, Construction, Engineer Project, Super-Market

Constraction:

Tittle
Copper Clad Cable mineral Cable BBTRZ/BBTRQ 4*70+1*35 flexible mineral insulated fireproof cable
Insulation
XLPE, LSOH, Flame retardant mineral
Jacket
Polyolefin
Conductor
Oxgen free pure copper
Layer
Mineral fire insolation
Type
low to high voltage
Application
Building, industrial, airport, power station, power supply and others
Core type
Solid or Stranded Copper
Brand name
LineGiant
colour:
Orange, Black, cunstomized
Rated voltage
600/1000V
MOQ
100 meters
Certification
TUV,CCC,ISO9001,CE,UL,ROHS
Package
Wooden Drum
Payment
T/T,L/C, Western Union, Other
Working Voltage
0.6/1kv
Product name
Power cable
Feature
Excellent Resistance
Product name
Power cable
Feature
Excellent Resistance

Standards&Certificates:

BS 6387-2013 , BS 8491

▼ Technical parameters:

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 0.7 1.4 6.0 12.1
1×2.5 1 0.7 1.4 6.4 7.41
1×4 1 0.7 1.4 6.9 4.61
1×6 1 0.7 1.4 7.3 3.08
1×10 7 0.7 1.4 8.4 1.83
1×16 7 0.7 1.4 9.4 1.15
1×25 7 0.9 1.4 11.0 0.727
1×35 7 0.9 1.4 12.0 0.524
1×50 10 1.0 1.4 13.3 0.387
1×70 14 1.1 1.4 15.1 0.268
1×95 19 1.1 1.5 17.3 0.193
1×120 24 1.2 1.5 19.0 0.153
1×150 30 1.4 1.6 20.9 0.124
1×185 37 1.6 1.6 23.0 0.0991
1×240 48 1.7 1.7 25.7 0.0754
1×300 61 1.8 1.8 28.3 0.0601
1×400 61 2.0 1.9 31.6 0.0470
1×500 61 2.2 2.0 35.1 0.0366
1×630 61 2.4 2.2 42.1 0.0283

2. 2 Core&3 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 0.7 1.8 10.6 12.1
2×2.5 1 0.7 1.8 11.4 7.41
2×4 1 0.7 1.8 12.4 4.61
2×6 1 0.7 1.8 13.2 3.08
2×10 7 0.7 1.8 15.4 1.83
2×16 7 0.7 1.8 17.4 1.15
2×25 7 0.9 1.8 20.6 0.727
2×35 7 0.9 1.8 22.6 0.524
2×50 10 1.0 1.8 26.2 0.387
2×70 14 1.1 1.8 29.8 0.268
2×95 19 1.1 1.9 34.0 0.193
2×120 24 1.2 2.0 37.4 0.153
2×150 30 1.4 2.2 41.2 0.124
2×185 37 1.6 2.3 45.6 0.0991
2×240 48 1.7 2.5 51.0 0.0754
2×300 61 1.8 2.6 56.0 0.0601
2×400 61 2.0 2.9 62.6 0.0470
2×500 61 2.2 3.1 70.0 0.0366
2×630 61 2.4 3.3 83.6 0.0283
3×1.5 1 0.7 1.8 11.2 12.1
3×2.5 1 0.7 1.8 12.1 7.41
3×4 1 0.7 1.8 13.2 4.61
3×6 1 0.7 1.8 14.0 3.08
3×10 7 0.7 1.8 16.4 1.83
3×16 7 0.7 1.8 18.6 1.15
3×25 7 0.9 1.8 22.0 0.727
3×35 7 0.9 1.8 24.2 0.524
3×50 10 1.0 1.8 28.0 0.387
3×70 14 1.1 1.9 32.1 0.268
3×95 19 1.1 2.0 36.4 0.193
3×120 24 1.2 2.1 40.3 0.153
3×150 30 1.4 2.3 44.3 0.124
3×185 37 1.6 2.4 49.1 0.0991
3×240 48 1.7 2.6 54.9 0.0754
3×300 61 1.8 2.7 60.1 0.0601
3×400 61 2.0 3.0 67.4 0.0470
3×500 61 2.2 3.2 75.3 0.0366
3×630 61 2.4 3.5 90.0 0.0283

3. 4 Core&5 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 0.7 1.8 12.2 12.1
4×2.5 1 0.7 1.8 13.1 7.41
4×4 1 0.7 1.8 14.3 4.61
4×6 1 0.7 1.8 15.3 3.08
4×10 7 0.7 1.8 18.0 1.83
4×16 7 0.7 1.8 20.4 1.15
4×25 7 0.9 1.8 24.3 0.727
4×35 7 0.9 1.8 26.7 0.524
4×50 10 1.0 1.8 30.8 0.387
4×70 14 1.1 2.0 35.4 0.268
4×95 19 1.1 2.1 40.4 0.193
4×120 24 1.2 2.3 44.9 0.153
4×150 30 1.4 2.4 49.3 0.124
4×185 37 1.6 2.6 54.7 0.0991
4×240 48 1.7 2.8 61.0 0.0754
4×300 61 1.8 3.0 67.2 0.0601
4×400 61 2.0 3.3 75.3 0.0470
4×500 61 2.2 3.5 84.0 0.0366
4×630 61 2.4 3.8 100.5 0.0283
5×1.5 1 0.7 1.8 13.2 12.1
5×2.5 1 0.7 1.8 14.2 7.41
5×4 1 0.7 1.8 15.6 4.61
5×6 1 0.7 1.8 16.7 3.08
5×10 7 0.7 1.8 19.6 1.83
5×16 7 0.7 1.8 22.3 1.15
5×25 7 0.9 1.8 26.7 0.727
5×35 7 0.9 1.8 29.4 0.524
5×50 10 1.0 1.9 34.1 0.387
5×70 14 1.1 2.1 39.1 0.268
5×95 19 1.1 2.2 44.7 0.193
5×120 24 1.2 2.4 49.7 0.153
5×150 30 1.4 2.6 54.7 0.124
5×185 37 1.6 2.8 60.6 0.0991
5×240 48 1.7 3.0 67.7 0.0754
5×300 61 1.8 3.2 74.6 0.0601
5×400 61 2.0 3.5 83.4 0.0470
5×500 61 2.2 3.8 93.4 0.0366
5×630 61 2.4 4.1 111.7 0.0283

4. 3+1 Core & 3+2 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 0.7 1.8 12.9 7.41
3×4+1×2.5 1 0.7 1.8 14.0 4.61
3×6+1×4 1 0.7 1.8 15.1 3.08
3×10+1×6 7 0.7 1.8 17.3 1.83
3×16+1×10 7 0.7 1.8 19.8 1.15
3×25+1×16 7 0.9 1.8 23.3 0.727
3×35+1×16 7 0.9 1.8 25.1 0.524
3×50+1×25 10 1.0 1.8 29.4 0.387
3×70+1×35 14 1.1 1.9 33.5 0.268
3×95+1×50 19 1.1 2.1 38.1 0.193
3×120+1×70 24 1.2 2.2 42.5 0.153
3×150+1×70 30 1.4 2.3 45.8 0.124
3×185+1×95 37 1.6 2.5 51.2 0.0991
3×240+1×120 48 1.7 2.6 57.0 0.0754
3×300+1×150 61 1.8 2.8 62.6 0.0601
3×400+1×185 61 2.0 3.1 70.1 0.0470
3×500+1×240 61 2.2 3.3 78.3 0.0366
3×630+1×300 61 2.4 3.6 92.1 0.0283
3×2.5+2×1.5 1 0.7 1.8 13.8 7.41
3×4+2×2.5 1 0.7 1.8 15.1 4.61
3×6+2×4 1 0.7 1.8 16.2 3.08
3×10+2×6 7 0.7 1.8 18.5 1.83
3×16+2×10 7 0.7 1.8 21.3 1.15
3×25+2×16 7 0.9 1.8 24.9 0.727
3×35+2×16 7 0.9 1.8 26.6 0.524
3×50+2×25 10 1.0 1.8 31.4 0.387
3×70+2×35 14 1.1 2.0 35.6 0.268
3×95+2×50 19 1.1 2.1 40.4 0.193
3×120+2×70 24 1.2 2.3 45.5 0.153
3×150+2×70 30 1.4 2.4 48.5 0.124
3×185+2×95 37 1.6 2.5 54.2 0.0991
3×240+2×120 48 1.7 2.7 60.3 0.0754
3×300+2×150 61 1.8 2.9 66.5 0.0601
3×400+2×185 61 2.0 3.2 74.3 0.0470
3×500+2×240 61 2.2 3.5 83.1 0.0366
3×630+2×300 61 2.4 3.8 97.0 0.0283

5. 4+1 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×2.5+1×1.5 1 0.7 1.8 14.0 7.41
4×4+1×2.5 1 0.7 1.8 15.3 4.61
4×6+1×4 1 0.7 1.8 16.5 3.08
4×10+1×6 7 0.7 1.8 19.1 1.83
4×16+1×10 7 0.7 1.8 21.8 1.15
4×25+1×16 7 0.9 1.8 25.8 0.727
4×35+1×16 7 0.9 1.8 28.0 0.524
4×50+1×25 10 1.0 1.9 32.8 0.387
4×70+1×35 14 1.1 2.0 37.3 0.268
4×95+1×50 19 1.1 2.2 42.7 0.193
4×120+1×70 24 1.2 2.3 47.5 0.153
4×150+1×70 30 1.4 2.5 51.6 0.124
4×185+1×95 37 1.6 2.6 57.4 0.0991
4×240+1×120 48 1.7 2.9 64.1 0.0754
4×300+1×150 61 1.8 3.1 70.6 0.0601
4×400+1×185 61 2.0 3.4 78.9 0.0470
4×500+1×240 61 2.2 3.6 88.2 0.0366
4×630+1×300 61 2.4 3.9 104.3 0.0283

Company information:

30 years of experience in R & D, production and sales of wire and cable.

Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.

Annual revenue is about 500 million US dollars.

CNAS laboratory, more than 100 testing reports.

Products are widely used in real estate, municipal, industrial support, mobile communications etc

Copper Conductor Mineral Filler Mi Cable , LSZH Jacket Micc Wire

Copper Conductor Mineral Filler Mi Cable , LSZH Jacket Micc Wire

Inquiry Cart 0