SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD

SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD

Manufacturer from China
Verified Supplier
5 Years
Home / Products / Low Smoke Halogen Free Cable /

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor

Contact Now
SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissCoco
Contact Now

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor

Ask Latest Price
Video Channel
Brand Name :DONGJIAXIN
Model Number :WDZ-YJV
Certification :IEC, Rosh,CCC
Place of Origin :CHINA
MOQ :Negotiable
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :100KM/Week
Delivery Time :7-15 working days
Packaging Details :Steel wooden drum
Model name :WDZ-YJV
Rated Voltage :0.6/1kV
specification :1.5~600mm2
insulator :XLPE
Conductor Type :Stranded Bear Copper
Sheath :pvc
High Light :lshf cable, lszh power cables, 4 Core Fire Resistant Cable
Application :industrial , home appliance , low voltage installation system,
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

WDZ YJV Type 4 Core Fire Resistant Cable , XLPE LZSH Cable Cu - Conductor

Fire resistant cable Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Fire resistant cable Construction

1. Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
6. Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor

Product type Conductor structure(mm) Insulation thickness(mm) Sheath thickness(mm) Approx. cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 0.8 1.4 5.2 12.1
1×2.5 1 0.8 1.4 5.6 7.41
1×4 1 1.0 1.4 6.0 4.61
1×6 1 1.0 1.4 6.5 3.08
1×10 7 1.0 1.4 7.6 1.83
1×16 7 1.0 1.4 8.6 1.15
1×25 7 1.2 1.4 10.2 0.727
1×35 7 1.2 1.4 11.2 0.524
1×50 10 1.4 1.4 12.5 0.387
1×70 14 1.4 1.4 14.3 0.268
1×95 19 1.6 1.5 16.5 0.193
1×120 24 1.6 1.5 18.2 0.153
1×150 30 1.8 1.6 20.1 0.124
1×185 37 2.0 1.7 22.2 0.0991
1×240 48 2.2 1.8 24.9 0.0754
1×300 61 2.4 1.9 27.5 0.0601
1×400 61 2.6 2.0 30.8 0.0470

INSTALLATION METHOD DETAILS

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
B1 – Electroduct in brickwork (Single-core) B1 – Electroduct in brickwork (multi-core) C – On the wall  C – On the ceiling
WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
C – Non-perforated tray F – Perforated tray (Single-core) F – Perforated tray (multi-core) F –Suspended (Single-core)
WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
E – Suspended (multi-core) B2 – Construction space B2 – Construction space B1 – Electroduct (Single-core)
WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
B2 – Electroduct (Multi-core) B2 – Closed raceway embedded in floor (multi-core) B2 – Closed raceway embedded in floor (multi-core) B1 – Ventilated raceway embedded in floor
WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
C – Embedded in the brickwork D – Buried in additional mechanical protection

* Dimensions and specifications may be changed without prior notice.

Standards&Certificates:
International: IEC 60502-1
National:GB/ T 12706.1-2008

Packing&Delivery:

We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.


▼ Cable Drum Data:

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

▼ Delivery Port :

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor
Port of Shenzhen Port of Hongkong

Port of Guangzhou

▼ Technical parameters:

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 0.7 1.4 6.0 12.1
1×2.5 1 0.7 1.4 6.4 7.41
1×4 1 0.7 1.4 6.9 4.61
1×6 1 0.7 1.4 7.3 3.08
1×10 7 0.7 1.4 8.4 1.83
1×16 7 0.7 1.4 9.4 1.15
1×25 7 0.9 1.4 11.0 0.727
1×35 7 0.9 1.4 12.0 0.524
1×50 10 1.0 1.4 13.3 0.387
1×70 14 1.1 1.4 15.1 0.268
1×95 19 1.1 1.5 17.3 0.193
1×120 24 1.2 1.5 19.0 0.153
1×150 30 1.4 1.6 20.9 0.124
1×185 37 1.6 1.6 23.0 0.0991
1×240 48 1.7 1.7 25.7 0.0754
1×300 61 1.8 1.8 28.3 0.0601
1×400 61 2.0 1.9 31.6 0.0470
1×500 61 2.2 2.0 35.1 0.0366
1×630 61 2.4 2.2 42.1 0.0283

2. 2 Core&3 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 0.7 1.8 10.6 12.1
2×2.5 1 0.7 1.8 11.4 7.41
2×4 1 0.7 1.8 12.4 4.61
2×6 1 0.7 1.8 13.2 3.08
2×10 7 0.7 1.8 15.4 1.83
2×16 7 0.7 1.8 17.4 1.15
2×25 7 0.9 1.8 20.6 0.727
2×35 7 0.9 1.8 22.6 0.524
2×50 10 1.0 1.8 26.2 0.387
2×70 14 1.1 1.8 29.8 0.268
2×95 19 1.1 1.9 34.0 0.193
2×120 24 1.2 2.0 37.4 0.153
2×150 30 1.4 2.2 41.2 0.124
2×185 37 1.6 2.3 45.6 0.0991
2×240 48 1.7 2.5 51.0 0.0754
2×300 61 1.8 2.6 56.0 0.0601
2×400 61 2.0 2.9 62.6 0.0470
2×500 61 2.2 3.1 70.0 0.0366
2×630 61 2.4 3.3 83.6 0.0283
3×1.5 1 0.7 1.8 11.2 12.1
3×2.5 1 0.7 1.8 12.1 7.41
3×4 1 0.7 1.8 13.2 4.61
3×6 1 0.7 1.8 14.0 3.08
3×10 7 0.7 1.8 16.4 1.83
3×16 7 0.7 1.8 18.6 1.15
3×25 7 0.9 1.8 22.0 0.727
3×35 7 0.9 1.8 24.2 0.524
3×50 10 1.0 1.8 28.0 0.387
3×70 14 1.1 1.9 32.1 0.268
3×95 19 1.1 2.0 36.4 0.193
3×120 24 1.2 2.1 40.3 0.153
3×150 30 1.4 2.3 44.3 0.124
3×185 37 1.6 2.4 49.1 0.0991
3×240 48 1.7 2.6 54.9 0.0754
3×300 61 1.8 2.7 60.1 0.0601
3×400 61 2.0 3.0 67.4 0.0470
3×500 61 2.2 3.2 75.3 0.0366
3×630 61 2.4 3.5 90.0 0.0283

3. 4 Core&5 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 0.7 1.8 12.2 12.1
4×2.5 1 0.7 1.8 13.1 7.41
4×4 1 0.7 1.8 14.3 4.61
4×6 1 0.7 1.8 15.3 3.08
4×10 7 0.7 1.8 18.0 1.83
4×16 7 0.7 1.8 20.4 1.15
4×25 7 0.9 1.8 24.3 0.727
4×35 7 0.9 1.8 26.7 0.524
4×50 10 1.0 1.8 30.8 0.387
4×70 14 1.1 2.0 35.4 0.268
4×95 19 1.1 2.1 40.4 0.193
4×120 24 1.2 2.3 44.9 0.153
4×150 30 1.4 2.4 49.3 0.124
4×185 37 1.6 2.6 54.7 0.0991
4×240 48 1.7 2.8 61.0 0.0754
4×300 61 1.8 3.0 67.2 0.0601
4×400 61 2.0 3.3 75.3 0.0470
4×500 61 2.2 3.5 84.0 0.0366
4×630 61 2.4 3.8 100.5 0.0283
5×1.5 1 0.7 1.8 13.2 12.1
5×2.5 1 0.7 1.8 14.2 7.41
5×4 1 0.7 1.8 15.6 4.61
5×6 1 0.7 1.8 16.7 3.08
5×10 7 0.7 1.8 19.6 1.83
5×16 7 0.7 1.8 22.3 1.15
5×25 7 0.9 1.8 26.7 0.727
5×35 7 0.9 1.8 29.4 0.524
5×50 10 1.0 1.9 34.1 0.387
5×70 14 1.1 2.1 39.1 0.268
5×95 19 1.1 2.2 44.7 0.193
5×120 24 1.2 2.4 49.7 0.153
5×150 30 1.4 2.6 54.7 0.124
5×185 37 1.6 2.8 60.6 0.0991
5×240 48 1.7 3.0 67.7 0.0754
5×300 61 1.8 3.2 74.6 0.0601
5×400 61 2.0 3.5 83.4 0.0470
5×500 61 2.2 3.8 93.4 0.0366
5×630 61 2.4 4.1 111.7 0.0283

4. 3+1 Core & 3+2 Core

Cross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 0.7 1.8 12.9 7.41
3×4+1×2.5 1 0.7 1.8 14.0 4.61
3×6+1×4 1 0.7 1.8 15.1 3.08
3×10+1×6 7 0.7 1.8 17.3 1.83
3×16+1×10 7 0.7 1.8 19.8 1.15
3×25+1×16 7 0.9 1.8 23.3 0.727
3×35+1×16 7 0.9 1.8 25.1 0.524
3×50+1×25 10 1.0 1.8 29.4 0.387
3×70+1×35 14 1.1 1.9 33.5 0.268
3×95+1×50 19 1.1 2.1 38.1 0.193
3×120+1×70 24 1.2 2.2 42.5 0.153
3×150+1×70 30 1.4 2.3 45.8 0.124
3×185+1×95 37 1.6 2.5 51.2 0.0991
3×240+1×120 48 1.7 2.6 57.0 0.0754
3×300+1×150 61 1.8 2.8 62.6 0.0601
3×400+1×185 61 2.0 3.1 70.1 0.0470
3×500+1×240 61 2.2 3.3 78.3 0.0366
3×630+1×300 61 2.4 3.6 92.1 0.0283
3×2.5+2×1.5 1 0.7 1.8 13.8 7.41
3×4+2×2.5 1 0.7 1.8 15.1 4.61
3×6+2×4 1 0.7 1.8 16.2 3.08
3×10+2×6 7 0.7 1.8 18.5 1.83
3×16+2×10 7 0.7 1.8 21.3 1.15
3×25+2×16 7 0.9 1.8 24.9 0.727
3×35+2×16 7 0.9 1.8 26.6 0.524
3×50+2×25 10 1.0 1.8 31.4 0.387
3×70+2×35 14 1.1 2.0 35.6 0.268
3×95+2×50 19 1.1 2.1 40.4 0.193
3×120+2×70 24 1.2 2.3 45.5 0.153
3×150+2×70 30 1.4 2.4 48.5 0.124
3×185+2×95 37 1.6 2.5 54.2 0.0991
3×240+2×120 48 1.7 2.7 60.3 0.0754
3×300+2×150 61 1.8 2.9 66.5 0.0601
3×400+2×185 61 2.0 3.2 74.3 0.0470
3×500+2×240 61 2.2 3.5 83.1 0.0366
3×630+2×300 61 2.4 3.8 97.0 0.0283

Ordering Options:
For prompt quotation / supplies please make sure your inquiries and your orders are securing the following data :

1 International or Special Standard. (Alternatively, the precise usage of the cable.)
2 Rated voltage.
3 Copper or Aluminium conductors.
4 Size of each conductor.
5 Insulation material : PVC XLPE or others.
6 Number and identification of conductors.
7 Other requirements.
8 Packing.
9 Required delivery time.
10 Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

Company information:

30 years of experience in R & D, production and sales of wire and cable.

Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.

Annual revenue is about 500 million US dollars.

CNAS laboratory, more than 100 testing reports.

Products are widely used in real estate, municipal, industrial support, mobile communications etc

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor

WDZ-YJY N2X2Y 4 Core LZSH Halogen Free Flame Retardant Cables Cu Conductor

IEC, Rosh,CCC
Inquiry Cart 0