YTTW RTTZ Flame Retardant Power Cable , 3×70+1×35MM2 Metallic Sheath Halogen Free Wire

Contact Now
SHENZHEN DONGJIAXIN WIRE&CABLE CO.,LTD
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissCoco
Contact Now

YTTW RTTZ Flame Retardant Power Cable , 3×70+1×35MM2 Metallic Sheath Halogen Free Wire

Ask Latest Price
Video Channel
Brand Name :DONGJIAXIN
Model Number :YTTW、YTTWY
Certification :ISO
Place of Origin :CHINA
MOQ :Negotiable
Price :Negotiable
Payment Terms :L/C, T/T, Western Union, MoneyGram
Supply Ability :10000M/Day
Delivery Time :7-15 working days
Packaging Details :Steel wooden drum, Coil In Foil / Drum
Model Name :YTTW、YTTWY
Conductor type :annealed copper (stranded core)
Size :1.5~630mm²
Voltage Rate :0.6/1kV
High Light :YTTW YTTWY Mineral Insulated Cables
Insulation :Mica Tape + Mineral Material
Sheath :Corrugated Copper
applicaiton :Heating
Item :flame retardant low smoke cables
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

YTTW RTTZ Fire Retardant Cable Corrugated Copper Metallic Sheath CCC Approved

Mineral insulated Fire resistance cable

YTTW, YTTWY, RTTW, Mineral Insulated Cables, MICC Fire Resistant Cables, Mineral Insulated Copper Cables, BS 6387 Mineral Insulated Cables, GB/T 34926-2017 Mineral Insulated Cables.

▼ Cable Featurers:

— Flame Retardant
— High Operating Temperatures
— LSOH Halogen-free
— Great Mechanical Strength
— Competitive Installed Cost
— Public Places

Our DJX cables provide outstanding electrical and fire-proof properties, and are halogen free.


The design, construction and testing are compliant with international standard IEC60502 and testing standard EN 50200 (PH-90),with standing temperatures of 840 °C for 90 minutes, which means they are capable of remaining in working order despite the most extreme fire conditions. Hence they are known as FIRE RESISTANT cables.


This type of cable is made up of single and multi-cores 600/1000V cables Service Temperature 90°C Emergency Overload Temperature 105°C Short-Circuit Temperature 250°C


Installation of these cables is essential in safety circuits (detection and alarm circuits,evacuation and fire-fighting systems).

Cable structure
YTTW RTTZ Flame Retardant Power Cable , 3×70+1×35MM2 Metallic Sheath Halogen Free Wire Conductor Stranded copper conductor class 2
Insulation mica tape1, flame retardant
Filler Glass yarns
core wraping Core wrapping with glass-fibre tape as flame-protection
Sheath Corrugated Copper
Outer covering (Optional) Anticorrosion Outer Sheath PVC
USAGE CHARACTERISTICS
Service Temperature 90°C
Emergency Overload Temperature 105°C
Short-Circuit Temperature 250°C
Laying Temperature should not be lower than 0°C
Minimum bending radius when laying Single core: r = 6 x cable outer diameter
Sheath colour The standard color is orange, other colors are available.

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×10 7 0.7 0.4 11.0 1.83
1×16 7 0.7 0.4 11.0 1.15
1×25 7 0.7 0.4 12.0 0.727
1×35 7 0.7 0.4 13.0 0.524
1×50 10 0.7 0.5 15.0 0.387
1×70 14 0.7 0.5 16.0 0.268
1×95 19 0.9 0.5 18.0 0.193
1×120 24 0.9 0.5 21.0 0.153
1×150 30 1.0 0.5 22.0 0.124
1×185 37 1.1 0.5 24.0 0.0991
1×240 48 1.1 0.6 28.0 0.0754
1×300 61 1.2 0.6 30.0 0.0601
1×400 61 1.4 0.6 33.0 0.0470

2. 2 Core&3 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 1.6 0.4 11.0 12.1
2×2.5 1 1.7 0.4 11.0 7.41
2×4 1 1.8 0.4 12.0 4.61
2×6 1 2.0 0.4 12.0 3.08
2×10 7 2.2 0.4 14.0 1.83
2×16 7 2.4 0.4 16.0 1.15
2×25 7 0.7 0.5 20.0 0.727
2×35 7 0.7 0.5 22.0 0.524
2×50 10 0.7 0.5 24.0 0.387
2×70 14 0.7 0.5 29.0 0.268
2×95 19 0.7 0.5 33.0 0.193
2×120 24 0.7 0.5 36.0 0.153
2×150 30 0.9 0.6 38.0 0.124
3×1.5 1 0.9 0.4 11.0 12.1
3×2.5 1 1.0 0.4 11.0 7.41
3×4 1 1.1 0.4 12.0 4.61
3×6 1 1.1 0.4 13.0 3.08
3×10 7 1.2 0.4 15.0 1.83
3×16 7 1.4 0.4 17.0 1.15
3×25 7 1.6 0.5 21.0 0.727
3×35 7 1.7 0.5 23.0 0.524
3×50 10 1.8 0.5 27.0 0.387
3×70 14 2.0 0.6 27.0 0.268
3×95 19 2.2 0.6 30.0 0.193
3×120 24 2.4 0.6 33.0 0.153
3×150 30 0.7 0.6 36.0 0.124

3. 4 Core&5 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 0.7 0.4 11.0 12.1
4×2.5 1 0.7 0.4 12.0 7.41
4×4 1 0.7 0.4 13.0 4.61
4×6 1 0.7 0.4 14.0 3.08
4×10 7 0.7 0.5 17.0 1.83
4×16 7 0.9 0.5 20.0 1.15
4×25 7 0.9 0.5 23.0 0.727
4×35 7 1.0 0.5 26.0 0.524
4×50 10 1.1 0.5 30.0 0.387
4×70 14 1.1 0.6 31.0 0.268
4×95 19 1.2 0.6 34.0 0.193
4×120 24 1.4 0.6 37.0 0.153
4×150 30 1.6 0.6 41.0 0.124
5×1.5 1 1.7 0.4 12.0 12.1
5×2.5 1 1.8 0.4 13.0 7.41
5×4 1 2.0 0.4 14.0 4.61
5×6 1 2.2 0.4 16.0 3.08
5×10 7 2.4 0.5 19.0 1.83
5×16 7 0.7 0.5 22.0 1.15
5×25 7 0.7 0.5 26.0 0.727
5×35 7 0.7 0.5 29.0 0.524
5×50 10 0.7 0.5 32.0 0.387
5×70 14 0.7 0.6 34.0 0.268
5×95 19 0.7 0.6 38.0 0.193
5×120 24 0.9 0.6 42.0 0.153
5×150 30 0.9 0.6 46.0 0.124

4. 3+1 Core & 3+2 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 1.0 0.4 12.0 7.41
3×4+1×2.5 1 1.1 0.4 13.0 4.61
3×6+1×4 1 1.1 0.4 14.0 3.08
3×10+1×6 7 1.2 0.5 16.0 1.83
3×16+1×10 7 1.4 0.5 20.0 1.15
3×25+1×16 7 1.6 0.5 23.0 0.727
3×35+1×16 7 1.7 0.5 24.0 0.524
3×50+1×25 10 1.8 0.5 28.0 0.387
3×70+1×35 14 2.0 0.6 31.0 0.268
3×95+1×50 19 2.2 0.6 34.0 0.193
3×120+1×70 24 2.4 0.6 37.0 0.153
3×150+1×70 30 0.7 0.6 40.0 0.124
3×2.5+2×1.5 1 0.7 0.4 12.0 7.41
3×4+2×2.5 1 0.7 0.4 14.0 4.61
3×6+2×4 1 0.7 0.4 15.0 3.08
3×10+2×6 7 0.7 0.5 17.0 1.83
3×16+2×10 7 0.9 0.5 21.0 1.15
3×25+2×16 7 0.9 0.5 24.0 0.727
3×35+2×16 7 1.0 0.5 26.0 0.524
3×50+2×25 10 1.1 0.6 30.0 0.387
3×70+2×35 14 1.1 0.6 33.0 0.268
3×95+2×50 19 1.2 0.6 37.0 0.193
3×120+2×70 24 1.4 0.6 40.0 0.153
3×150+2×70 30 1.6 0.6 44.0 0.124

5. 4+1 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×2.5+1×1.5 1 1.7 0.4 13.0 7.41
4×4+1×2.5 1 1.8 0.4 14.0 4.61
4×6+1×4 1 2.0 0.4 15.0 3.08
4×10+1×6 7 2.2 0.5 18.0 1.83
4×16+1×10 7 2.4 0.5 21.0 1.15
4×25+1×16 7 0.7 0.5 25.0 0.727
4×35+1×16 7 0.7 0.6 29.0 0.524
4×50+1×25 10 0.7 0.6 32.0 0.387
4×70+1×35 14 0.7 0.6 34.0 0.268
4×95+1×50 19 0.7 0.6 38.0 0.193
4×120+1×70 24 0.9 0.6 41.0 0.153
4×150+1×70 30 0.9 0.6 45.0 0.124

Packing&Delivery:

We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.


▼ Cable Drum Data:

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
YTTW RTTZ Flame Retardant Power Cable , 3×70+1×35MM2 Metallic Sheath Halogen Free Wire 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

▼ Delivery Port :

YTTW RTTZ Flame Retardant Power Cable , 3×70+1×35MM2 Metallic Sheath Halogen Free Wire YTTW RTTZ Flame Retardant Power Cable , 3×70+1×35MM2 Metallic Sheath Halogen Free Wire YTTW RTTZ Flame Retardant Power Cable , 3×70+1×35MM2 Metallic Sheath Halogen Free Wire
Port of Shenzhen Port of Hongkong

Port of Guangzhou

Ordering Options:
For prompt quotation/supplies please make sure your inquiries and your orders are securing the following data :

1 International or Special Standard. (Alternatively, the precise usage of the cable.)
2 Rated voltage.
3 Copper or Aluminium conductors.
4 Size of each conductor.
5 Insulation material: PVC XLPE or others.
6 Number and identification of conductors.
7 Other requirements.
8 Packing.
9 Required delivery time.
10 Required validity.

If this all seems a little too technical for you, then why not get in touch with us. We look forward to assisting you in identifying the best products for your specific application and answering any questions you might have.

Inquiry Cart 0